Hi

When you encounter this issue of getting a ‘Runtime Operation Exception’ while logging into BPM Workspace, or find a similar log

ORABPEL-30017

Invalid task definition.
The task definition at default/PrjTaskReminderNotification!1.0*soa_5cb0ae06-9485-488f-91b1-1b2872276fb9/Initiator could not be read. The task definition is associated with workflow default/PrjTaskReminderNotification!1.0*soa_5cb0ae06-9485-488f-91b1-1b2872276fb9/Initiator.
Make sure that the task definition is available at the specified URL and that it is a valid XML document.

Here’s the solution.
This happens when there are more than one active record in BPM_CUBE_PROCESS table.
You just have to make sure that there is only one active record per process.

Execute the following query by connecting to the SOA_INFRA schema of the database

select processId, processName, compositeName, revision, status, from BPM_CUBE_PROCESS;

If it returns multiple records for the same ProcessName, make the status of all those entries to -1,commit and redeploy the process.
Now, you can see the process in the workspace without any problem

This entry was posted in BPM Workflows not appearing in P6 BPM portlet, Error in BPM Workspace, Invalid task definition, ORABPEL-30017, Runtime Operation Error, Unable to find BPM Processes in Workspace. Bookmark the permalink.

1 Response to Runtime Operation Error in BPM – ORABPEL-30017 – Invalid task definition

  1. Anonymous says:

    Thank you so much. This solved my bugging issue.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google photo

You are commenting using your Google account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s